Core Series
Blend: Mixes the clean input signal with the overdriven signal. The clean signal remains at unity gain while the volume of the overdriven signal is set by the Level knob, allowing for fine control of the blend ratio.
Tone: Controls the high frequency content of the sound. A variable low pass filter from 3kHz (ccw) to 8kHz (cw).
Level: Sets the volume of the overdriven signal.
Drive: Sets the amount of saturation in the overdriven signal.
Grunt: When engaged provides a massive low end boost to really thicken your sound.
Mid Boost: Gives a subtle 6dB boost from 300 Hz to 1kHz to help you cut through a bit more.
Input Impedance: 500kΩ
Output Impedance: 1kΩ
Current Consumption: ~17mA
Voltage: 9V DC (Center Negative)
Width: 75 mm / 2,95″
Length: 111 mm/ 4,37″
Height: 43 mm / 1,69″
Weight: 250 g / 0,55 lb
The Microtubes B3K has a current draw of 20mA. Only use a regulated 9V DC adapter with a center-negative plug. Unregulated power supplies and/or higher voltages may result in suboptimal noise performance and even damage your unit, voiding the warranty.
To activate the warranty, we encourage you to register your product on: http://mypedal.darkglass.com and enter the serial number on the back of your pedal. Please contact us via email support@darkglass.com before shipping a product to us.
In the interest of continuous improvement, specifications are subject to change without notice. If you have any questions, please don’t hesitate to contact us at www.darkglass.com The manufacturer claims that the above product fulfils the requirements as set by EN55013, EN55020, EN60555-2, EN60555-3, RoHS, WEEE.
1176®, and SSL® are registered trademarks of their respective companies. Names of factory modes are intended for descriptive purposes only and should not be construed as an endorsement or affiliation with the companies or products named.
This equipment has been tested and found to comply with the limits for a Class B Digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in residential installations.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: